Reagent Center

DNA Marker

  • Bio DL100 MORE
    Product Details:

    Cat#:BSA22S1

    Introduction

    1. Bio DL100 already contains 1 × Loading Buffer DNA solution, only 5 μ l ladders direct for electrophoresis, very easy to use. The Bio DL100 includes the DNA fragments in length of 100bp, 200bp, 300bp, 400bp, 500bp, 600bp, 700bp, 800bp, 900bp, 1000bp, 1500bp.
    2. Directly load 5µl of the ladder each time, this will provide 50ng DNA per fragment.



    Product Features:

    Bio DL100       250µl

    Storage

    Bio DL100 should be stored at 2–8 ℃ or at –20 ℃ in a constant-temperature fridge or freezer. Please avoid freezing and thaw time after time.

    NOTE

    1. When the width of electrophoresis sample hole is less than 6mm, only 5 μ l product can get the clear electrophoresis band. If the sample hole is widened, the products volume should be appropriately increased.
    2. For  DNA  electrophoresis,  the purity of  agarose  will influence  the definition of DNA band lot. Therefore, should choose the agarose in good quality for the electrophoresis.
    3. When doing agarose gel electrophoresis, the gel concentration is close bear on the DNA fragment separation effect. The bigger the agarose gel concentration, the better DNA separation effect of short fragment. Conversely, the smaller the concentration of agarose gel, more conducive to the long separation of DNA fragments.

     

    Experimental data:

    Manual download
  • Bio DL200 MORE
    Product Details:

    Cat :BSA23S1

    Introduction

    1. Bio DL200 already contains 1 × Loading Buffer DNA solution, only 5 μ l ladder direct for electrophoresis, very easy to use. The Bio DL200 includes  the  DNA  fragments  in  length  of 200bp, 400bp, 600bp, 800bp, 1000bp, 1200bp, 1400bp, 1600bp, 1800bp, 2000bp, 2500bp,4000bp,.
    2. Directly load 5µl of the ladder each time, this will provide 50ng DNA per fragment. 1000bp about 100ng.



    Product Features:

    Bio DL200                250µl

    Storage

    Bio DL200 should be stored at 2 – 8 ℃ or at – 20 ℃ in a constant-temperature fridge or freezer. Please avoid freezing and thaw time after time.

    NOTE

    1. When the width of electrophoresis sample hole is less than 6mm, only  5 μl product can get the clear electrophoresis band. If the sample hole is widened, the products volume should be appropriately increased.
    2. For DNA electrophoresis,  the purity of  agarose  will  influence the definition of DNA band lot. Therefore, should choose the agarose in good quality for the electrophoresis.
    3. When doing agarose gel electrophoresis, the gel concentration is close bear on the DNA fragment separation effect. The bigger the agarose gel concentration, the better DNA separation effect of short fragment. Conversely, the smaller the concentration of agarose gel, more conducive to the long separation of DNA fragments.

     

    Experimental data:

    Manual download
  • Bio DL2000 MORE
    Product Details:

    Cat#:BSA21S1

    Introduction

    • Bio DL2000 already contains 1 × Loading Buffer DNA solution, only 5 μ l ladder direct for electrophoresis, very easy to use. The Bio DL2000 includes the DNA fragments in length of 100bp, 250bp, 500bp, 750bp, 1000bp, 2000bp.
    • Directly load 5µl of the ladder each time, this will provide 50ng DNA per fragment, 750bp about 100ng.


    Product Features:

    Bio DL2000                250µl

     Storage

    Bio DL2000 should be stored at 2–8 ℃ or at –20 ℃ in a constant-temperature fridge or freezer. Please avoid freezing and thaw time after time.

    NOTE

    1. When the width of electrophoresis sample hole is less than 6mm, only 5 μ l product can get the clear electrophoresis band. If the sample hole is widened, the products volume should be appropriately increased.
    2. For  DNA  electrophoresis,  the purity of  agarose  will influence  the definition of DNA band lot. Therefore, should choose the agarose in good quality for the electrophoresis.
    3. When doing agarose gel electrophoresis, the gel concentration is close bear on the DNA fragment separation effect. The bigger the agarose gel concentration, the better DNA separation effect of short fragment. Conversely, the smaller the concentration of agarose gel, more conducive to the long separation of DNA fragments.

     

    Experimental data:

    Manual download
  • Bio Marker Ⅴ MORE
    Product Details:

    Cat#:BSA28S1

    Introduction

    1. Bio Marker  already contains 1× Loading Buffer DNA solution, only 5 μ l ladder direct for  electrophoresis, very easy to use. The Bio Marker includes the DNA fragments in length of 300bp, 500bp, 1000bp, 1500bp, 2000bp, 2500bp.
    2. Directly load 5µl of the ladder each time, this will provide 50ng DNA per fragment. 1500bp about 100ng.

     



    Product Features:

    Bio Marker Ⅴ        250µl

    Storage

    Bio Marker should be stored at 2–8 ℃ or at –20 ℃ in a constant-temperature fridge or freezer. Please avoid freezing and thaw time after time.

    NOTE

    1. When the width of electrophoresis sample hole is less than 6mm, only  5 μl product can get the clear electrophoresis band. If the sample hole is widened, the products volume should be appropriately increased.
    2. For  DNA  electrophoresis,  the purity of  agarose  will influence  the definition of DNA band lot. Therefore, should choose the agarose in good quality for the electrophoresis.
    3. When doing agarose gel electrophoresis, the gel concentration is close bear on the DNA fragment separation effect. The bigger the agarose gel concentration, the better DNA separation effect of short fragment. Conversely, the smaller the concentration of agarose gel, more conducive to the long separation of DNA fragments.


    Experimental data:

    Manual download
  • Bio Marker I MORE
    Product Details:

    Cat#:BSA24S1

    Introduction
    1. Bio MarkerⅠ already contains 1 × Loading Buffer DNA solution, only 5 μ l ladder direct for electrophoresis, very easy to use. The Bio MarkerⅠincludes the DNA fragments in length of 100bp, 200bp,300bp,400bp, 500bp, 600bp.
    2. Directly load 5µl of the ladder each time, this will provide 50ng DNA per fragment. 500bp about 100ng.


    Product Features:

    Bio Marker I                250µl

    Storage

    Bio Marker I should be stored at 2–8 ℃ or at –20 ℃ in a constant-temperature fridge or freezer. Please avoid freezing and thaw time after time.

    NOTE

    1. When the width of electrophoresis sample hole is less than 6mm, only  5 μl product can get the clear electrophoresis band. If the sample hole is widened, the products volume should be appropriately increased.
    2. For DNA electrophoresis,  the purity of  agarose  will  influence the definition of DNA band lot. Therefore, should choose the agarose in good quality for the electrophoresis.
    3. When doing agarose gel electrophoresis, the gel concentration is close bear on the DNA fragment separation effect. The bigger the agarose gel concentration, the better DNA separation effect of short fragment. Conversely, the smaller the concentration of agarose gel, more conducive to the long separation of DNA fragments.

     

    Experimental data:

    Manual download
  • Bio Marker Ⅳ MORE
    Product Details:

    Cat#:BSA27S1

    Introduction

        Bio Marker already contains 1 × Loading Buffer DNA solution, only 5 μ l ladder direct for electrophoresis, very easy to use. The Bio Marker includes the DNA fragments in length of 200bp, 400bp, 700bp, 1000bp, 1500bp, 2000bp.
        Directly load 5µl of the ladder each time, this will provide 50ng DNA per fragment. 1000bp about 100ng.


    Product Features:

    Bio Marker Ⅳ        250µl

    Storage
    Bio Marker should be stored at 2–8 ℃ or at –20 ℃ in a constant-temperature fridge or freezer. Please avoid freezing and thaw time after time.

    NOTE
    1. When the width of electrophoresis sample hole is less than 6mm, only  5 μl product can get the clear electrophoresis band. If the sample hole is widened, the products volume should be appropriately increased.
    2. For DNA electrophoresis,  the purity of  agarose  will  influence the definition   of DNA band lot. Therefore, should choose the agarose in good quality for the electrophoresis.
    3. When doing agarose gel electrophoresis, the gel concentration is close bear on the DNA fragment separation effect. The bigger the agarose gel concentration, the better DNA separation effect of short fragment. Conversely, the smaller the concentration of agarose gel, more conducive to the long separation of DNA fragments.

     

    Experimental data:

    Manual download
  • Bio Marker Ⅱ MORE
    Product Details:
    Introduction
    1. Bio Marker already contains 1 × Loading Buffer DNA solution, only 5 μ l ladder direct for electrophoresis,  very  easy to  use.  The Bio Marker " includes the DNA fragments in length of 100bp,300bp, 500bp, 700bp, 900bp, 1200bp.
    2. Directly load 5µl of the ladder each time, this will provide 50ng DNA per fragment. 700bp about 100ng.
    Product Features:

    Bio Marker Ⅱ        250µl

    Storage

    Bio Marker should be stored at 2–8 ℃ or at –20 ℃ in a constant-temperature fridge or freezer. Please avoid freezing and thaw time after time.

    NOTE
    1. When the width of electrophoresis sample hole is less than 6mm, only  5 μl product can get the clear electrophoresis band. If the sample hole is widened, the products volume should be appropriately increased.
    2. For DNA electrophoresis,  the purity of  agarose  will  influence the definition of DNA band lot. Therefore, should choose the agarose in good quality for the electrophoresis.
    3. When doing agarose gel electrophoresis, the gel concentration is close bear on the DNA fragment separation effect. The bigger the agarose gel concentration, the better DNA separation effect of short fragment. Conversely, the smaller the concentration of agarose gel, more conducive to the long separation of DNA fragments.


    Experimental data:

    Manual download
  • Bio Marker Ⅲ MORE
    Product Details:
    Introduction

    Bio Marker already contains 1 × Loading Buffer DNA solution, only 5 μ l ladder direct for electrophoresis,  very  easy to  use.  The Bio Marker includes the DNA fragments in length of 200bp, 500bp, 800bp, 1200bp, 2000bp, 3000bp, 4000bp.
    Directly load 5µl of the ladder each time, this will provide 50ng DNA per fragment. 1200bp about 100ng.

    Product Features:

    Bio Marker Ⅲ    250µl

    Storage

    Bio Marker should be stored at 2–8 ℃ or at –20 ℃ in a constant-temperature fridge or freezer. Please avoid freezing and thaw time after time.

    NOTE

    1. When the width of electrophoresis sample hole is less than 6mm, only  5 μl product can get the clear electrophoresis band. If the sample hole is widened, the products volume should be appropriately increased.
    2. For DNA electrophoresis,  the purity of  agarose  will  influence the definition of DNA band lot. Therefore, should choose the agarose in good quality for the electrophoresis.
    3. When doing agarose gel electrophoresis, the gel concentration is close bear on the DNA fragment separation effect. The bigger the agarose gel concentration, the better DNA separation effect of short fragment. Conversely, the smaller the concentration of agarose gel, more conducive to the long separation of DNA fragments.


    Experimental data:

    Manual download
  • Bio PCR Q MORE
    Product Details:

    Cat#:BSA29S1

    Introduction

    Bio PCR Q already contains 1 × Loading   Buffer DNA solution, only 5 μ l ladder direct for electrophoresis, very easy  to to use. The Bio PCR Q includes the DNA fragments in length of 50bp,80bp, 100bp, 150bp, 200bp, 250bp and 300bp.

    Directly load 5µl of the ladder each time.


    Product Features:

    Bio PCR Q       250µl

    NOTE

    1. When the width of electrophoresis sample hole is less than 6mm, only  5 μl product can get the clear electrophoresis band. If the sample hole is widened, the products volume should be appropriately increased.
    2. For  DNA  electrophoresis,  the purity of  agarose  will influence  the  definition of DNA band lot. Therefore, should choose the agarose in good quality for the electrophoresis.
    3. When doing agarose gel electrophoresis, the gel concentration is close bear on the DNA fragment separation effect. The bigger the agarose gel concentration, the better DNA separation effect of short fragment. Conversely, the smaller the concentration of agarose gel, more conducive to the long separation of DNA fragments.
    Experimental data:

    Manual download
  • Bio S50 MORE
    Product Details:

    Cat#:BSA30S1

    Introduction

    •     Bio S50 already contains 1 × Loading Buffer DNA solution, only 5 μ l ladder direct for electrophoresis, very easy to use. The Bio S50 includes the DNA fragments in length of 50bp, 100bp, 150bp, 200bp, 250bp, 300bp, 350bp, 400bp, 500bp.
    •     Directly load 5µl of the ladder each time, this will provide 50ng DNA per fragment. 300bp about 100ng.



    Product Features:

    Bio S50       250µl

    Storage

    Bio S50 should be stored at 2–8 ℃ or at –20 ℃ in a constant-temperature fridge or freezer. Please avoid freezing and thaw time after time.

    NOTE

    • When the width of electrophoresis sample hole is less than 6mm, only  5 μl product can get the clear electrophoresis band. If the sample hole is widened, the products volume should be appropriately increased.
    • For DNA electrophoresis,  the purity of  agarose  will  influence the definition   of  DNA band lot. Therefore, should choose the agarose in good quality for the electrophoresis.
    • When doing agarose gel electrophoresis, the gel concentration is close bear on the DNA fragment separation effect. The bigger the agarose gel concentration, the better DNA separation effect of short fragment. Conversely, the smaller the concentration of agarose gel, more conducive to the long separation of DNA fragments.

     


    Experimental data:

    Manual download
Privacy clause

Respect the user's privacy is a basic policy of Hangzhou Bioer user service. Hangzhou Boier will not disclosure user information to third parties or disclose their registration and preservation of non disclosure in Hangzhou Bioer platform, except in the following situations: (1)User's improper behavior caused leakage of privacy information ; (2)Caused by network, hacker attack, computer virus, government regulation, the reasons of the leakage, lost, stolen or tampered with other relevant legal requirements; (3)Law-enforcement agency asked Hangzhou Bioer to provide privacy information of the user; (4)Emergency situation when public life and property security is under threate.

Exemption clause

Hangzhou Bioer technology does not guarantee the accuracy, integrity and reliability of any content on this website and any content that may use these results. Hangzhou Bioer technology and related people can not guarantee that you can enter, browse and use this website at any time; Hangzhou Bioer technology on this website and its contents can not use and do not take any responsibility. The site links to other websites that Hangzhou itself is not recognized or undertake other Bioer technology content or the use of responsibility. Hangzhou Bioer technology and related people to enter, browse and use of the site, from the website to download any content or by any link to this site to other sites caused by viruses or other destructive programs on your computer system and any other software and hardware, IT system or property damage or loss does not bear any responsibility. Hangzhou Bioer technology and the relevant people do not bear any responsibility caused by the third party using illegal means to obtain the password, data and content into the site of any direct and indirect damage or loss . The final interpretation belong to Hangzhou Bioer Technology Co. Ltd.

Hangzhou Bioer reserves the right to correct, modify and update this statement at any time.

Copyright

This website from Hangzhou Bioer Technology Co. Ltd. (hereinafter referred to as "Hangzhou Bioer") the creation of any content of this website (including but not limited to text, data, graphics, images, voice or video) are copyright or related rights belong to Hangzhou Bioer. Hangzhou Bioer or related rights without prior written permission, you shall not in any way without permission to copy, reconstruction, spread, publishing, reprint, repost or display the contents of this website. Any unauthorized use of this site may violate the "Copyright Law of People's Republic of China " and other relevant laws and regulations and international conventions, Hangzhou Bioer fully pursue appropriate legal responsibility right.

Contact Us

Address: 1192 Bin An Rd, Hi-tech (Binjiang)District,Hangzhou,310053,P. R. China

Tel:0571-87774567

网上赚钱项目 股票配资电话销售话术录音 中联重科股票 福彩3d计划必中软件 湖北快3三形态走势图一 牛股股票推荐 重庆快乐10分任五遗漏 海南飞鱼彩票开奖结果 炒股票软件下载 云南快乐十分遗漏数据5 2018香港最快开奖结果